Feedthroughs
Raymond EMC offers a complete line of feedthroughs for passing radio frequencies and data through shielded enclosures.
Request PricingRF connectors for maximum effectiveness
Integrating an RF connector or a filtered feedthrough into a Raymond EMC product requires the use of a bulkhead connector panel to ensure optimum RF shielding effectiveness. Raymond RF can supply virtually any bulkhead mount RF connector including standard and precision connectors.
Full line of filtered feedthroughs
Raymond RF offers a line of D-subminiature filtered feedthroughs suitable for most data applications.
Filtered D-Subminiature Feedthrough Performance |
||||||||||||
Insertion loss – Decibels (dB) |
||||||||||||
Filter type |
capacitance |
3 dB Cut-off (MHz) |
5 MHz |
10 MHz |
20 MHz |
50 MHz |
100 MHz |
200 MHz |
500 MHz |
1 GHz |
2 GHz |
5 GHz |
J |
100 pF |
32 |
– |
– |
– |
2 |
6 |
11 |
27 |
40 |
43 |
40 |
A |
310 pF |
17 |
– |
– |
3 |
7 |
13 |
21 |
36 |
43 |
50 |
45 |
C |
1000 pF |
3.2 |
– |
5 |
9 |
19 |
30 |
43 |
62 |
70 |
68 |
63 |
K |
2500 pF |
1.3 |
8 |
5 |
18 |
33 |
45 |
58 |
73 |
78 |
70 |
65 |
E |
4000 pF |
0.8 |
8 |
13 |
20 |
35 |
48 |
61 |
76 |
80 |
70 |
65 |
The integration of a D-subminiature feedthrough filter into a Raymond EMC product may reduce the overall RF shielding effectiveness of the system to the levels outlined in the table above. The actual reduction would depend on cable length and jacket shield type both inside and outside of the system.
Two-year warranty
All Raymond EMC feedthroughs come with a two-year limited warranty against defective materials and craftsmanship and to retain the specified RF shielding effectiveness.