QuietChamber™ 10m
Raymond EMC’s RF shielded QuietChamber™ 10m enables compliant measurements at a 10-meter distance.
Request PricingFull turnkey solutions
Raymond EMC provides turnkey solutions that start with design and continue through to onsite installation, chamber testing and RF shielding effectiveness certification. We also build in all electrical, HVAC, life-saving system and seismic requirements.
Versatile design capability
Raymond EMC’s modular system is adaptable, and can be configured to meet unique client requirements.
Complete line of options
Clients work with our expert team to create custom solutions that can include:
- RF vestibules
- RF power line filters
- Internal electrical distribution
- RF signal filters
- Honeycomb waveguide air vents
- Bulkhead connector panels
- Waveguide pipe penetrations
- Architectural finishes
- Functional finishes
- Turntables
- EMC benches
- Antenna masts
- Control rooms
Contact us for more options.
Typical chamber performance
Normalized site attenuation (NSA) |
+/- 4 dB (200 MHz to 1GHz) |
Site voltage standing wave ratio (sVSWR) |
≤6 dB |
Field uniformity |
75% of 16 points, ≤6 dB, .5m x .5m |
RF shielding performance
Magnetic |
55 dB @ 10 kHz; 95dB @ 200 kHz, 100 dB @ 1 MHz |
Electric |
100 dB from 15 kHz to 100 MHz |
Plane wave |
100 dB from 100 MHz to 1 GHz |
Microwave |
100 dB at 10 GHz |
Compliance with industry standards
IEC 61000-4-3 |
Testing and measurement techniques – radiated, radio-frequency, electromagnetic field immunity test |
CISPR 16 |
Specifies equipment and methods for measuring disturbances and immunity to them at frequencies above 9 kHz |
Two-year warranty
All Raymond EMC QuietChambers™ come with a two-year limited warranty against defective materials and craftsmanship and to retain the specified RF shielding effectiveness.