Full turnkey solutions

Raymond EMC provides turnkey solutions that start with design and continue through to onsite installation and RF shielding effectiveness certification. We also build in all electrical, HVAC, life-saving system and seismic requirements.

Versatile design capability

Raymond EMC’s modular system is adaptable, and can be configured to meet unique client requirements.

RF shielding performance

Magnetic

55 dB @ 10 kHz; 95 dB @ 200 kHz, 100 dB @ 1 MHz

Electric

100 dB from 15 kHz to 100 MHz

Plane wave

100 dB from 100 MHz to 1 GHz

Microwave

100 dB at 10 GHz

Complete line of options

Clients work with our expert team to create custom solutions that can include:

  • RF vestibules
  • RF power line filters
  • Internal electrical distribution
  • RF signal filters
  • Honeycomb waveguide air vents
  • Bulkhead connector panels
  • Waveguide pipe penetrations
  • Architectural finishes
  • Functional finishes
  • Turntables
  • EMC benches

Compliance with industry standards

MIL-STD-461

United States military standard that describes how to test equipment for electromagnetic compatibility

*DO-160

Environmental conditions and test procedures for airborne equipment standard for the environmental testing of avionics hardware

*Optional standard

Two-year warranty